Removing the Internal Vector Controller
- Unscrew the 6 screws on the edges of the controller.
- Carefully unplug the three coloured phase wires
- Unplug the 6-pin hall sensor plug. Make sure to push on the little tab so that it comes out easily.
- Remove the controller.
Installing the Internal Vector Controller
From the motor, there is a 6-pin hall sensor plug and three coloured phase wires. Follow these steps to install the controller, or follow the video.
- Plug in the 6-pin hall sensor plug
- Plug in the three coloured phase wires. The order is yellow, blue, and green from the top left to the top right of the controller.
- Push the controller into the motor in a way that it fits nicely and is not resisting your push.
- Align the controller holes and tighten the 6 screws on the edges.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent