Hi, sorry to hear you are having issues.
This is a generic document so please use what applies to your situation.
Please refer the attached document VEC_Controller_Wiring_Diagram.jpg
A few things to note
- the elock must be connected to the B+ pole and a switch needs to be attached to power the controller on and off or at minimum a paperclip inserted to close the circuit and power up the controller.
- Depending on which controller you have the Yellow, Green and Blue phase wires may not be in the same order as shown in the diagram, The important thing is Yellow connects to U, Green to V and Blue to W.
- another key thing is the hall sensor plug. You really have to take a good look at to make sure all the pins in the plug are intact and straight. Also when plugging the hall sensor plug in, make sure no pins back out of the plug as it is pushed together.
When powering up the controller light should blink once and only once. If so the setup is correct and everything is working.
If it blinks once and then a series of flashes over and over again count how many flashes there are as these are error codes.